FIRE EQUIPMENT SERVICING PERTH
Portable fire extinguishers, hose reels, fire blankets, and hydrant systems serviced across Perth metro and regional WA to AS 1851:2012. Compliance certificates issued within 48 hours.
EQUIPMENT PTTS SERVICES
Portable Fire Extinguishers
Level 1, 2 and 4 services to AS 1851:2012 and AS 2444
Fire Hose Reels
Level 1 and 2 services to AS/NZS 1221 and AS 1851:2012
Fire Blankets
Annual Level 1 assessment to AS 1851:2012 - ideal for Class F fire environments
Hydrants and Sprinklers
Complex suppression systems via specialist partner contractors
WHO NEEDS FIRE EQUIPMENT SERVICING IN WA?
This applies to virtually every commercial, industrial, and public building in Perth, including offices, warehouses, factories, retail premises, hospitality venues, aged care facilities, childcare centres, schools, and construction sites.
Failing to maintain fire equipment to AS 1851 exposes a business to WorkSafe penalties, voided insurance claims, and significantly increased liability if a fire-related incident occurs on site. Over 95% of workplace fires can be extinguished if the correct equipment is used promptly, which is the data underpinning the mandatory servicing requirement.
WHS Act 2020 — AS 1851:2012
Every person conducting a business or undertaking (PCBU) with fire protection equipment on site has a legal duty to maintain that equipment in effective working order. AS 1851:2012 defines how and how often that maintenance must occur.
WHY PERTH BUSINESSES CHOOSE PTTS
FIRE EXTINGUISHER SERVICE LEVELS
AS 1851:2012 requires all portable fire extinguishers to be serviced every 6 months by a trained competent person. There are three service levels.
| Service level | Frequency | What it includes |
|---|---|---|
| Level 1 | Every 6 months | 21-point inspection covering condition, pressure, signage, accessibility, and mounting |
| Level 2 | Annual | All Level 1 checks plus 13 additional checks covering internal components, discharge mechanism, and hose condition |
| Level 4 | Every 5 years | Pressure testing and full element replacement. In most cases, replacement of the extinguisher is more cost-effective than a Level 4 service |
HOSE REEL SERVICE LEVELS
Fire hose reels are a substitute for extinguishers and are used for their ability to cover more surface area. According to the building code, fire hose reel compartments must be available in areas greater than 500sqm. This is not the only requirement for circumstances that require a hose reel however one of the more common apply requirements. Requirements will vary depending on building codes at time on construction.
In accordance to the AS/NZS 1221 & AS1851, fire hose reels must be tested every 6 months. There is 2 main types of tests for fire hose reels:
| Service level | Frequency | What it includes |
|---|---|---|
| Level 1 | Every 6 months | Visual assessment of external components, flow test, and leakage test |
| Level 2 | Annual | All Level 1 checks plus assessment of the hose, hose guide, bearings, and anchor points |
Level 1
Annual assessment
- Accessibility check to confirm the blanket is reachable and unobstructed
- Signage assessment to confirm correct fire blanket signage is present and visible
- Blanket and housing condition check for damage, contamination, or deterioration
FIRE BLANKET SERVICING
Fire blankets are used in predominantly in kitchen spaces as they are ideal for class F fires (Fires involving cooking oil and fats).
We also work closely and can organise contractors who assist with more complex fire suppression systems including sprinkler and hydrant testing. contact us to enquire more about this kind of servicing.
FIRE EQUIPMENT SERVICING PERTH: FREQUENTLY ASKED QUESTIONS
-
Yes, under the WHS Act 2020, PCBUs must maintain fire protection equipment in effective working order. AS 1851:2012 is the recognised compliance standard. Failure to maintain equipment to this standard can result in WorkSafe penalties, voided insurance, and increased liability in the event of a fire.
-
AS 1851:2012 requires portable fire extinguishers to be serviced every 6 months (Level 1), annually (Level 2), and every 5 years for a full pressure test and element replacement (Level 4). Most businesses will only encounter Level 1 and Level 2 services in routine compliance.
-
Every 6 months for a Level 1 service (visual assessment, flow and leakage test), and annually for a Level 2 service that also covers the hose, guide, bearings, and anchor points. Both are required under AS/NZS 1221 and AS 1851:2012.
-
A Class F fire involves cooking oils and fats. Water or standard dry powder extinguishers are not suitable for Class F fires and can make them worse. A fire blanket smothers the fire by cutting off oxygen and is the correct first-response tool in commercial kitchen environments.
-
Absolutely, and this is the most cost-effective approach. Many Perth businesses combine test and tag, RCD testing, fire equipment servicing, and emergency lighting inspection into a single visit, reducing cost and site disruption compared to separate bookings.
-
Yes, PTTS services fire equipment across Perth metro and regional WA including the South West, Goldfields, Mid West, and Gascoyne regions. Contact us to discuss scheduling for your regional site.
BOOK FIRE EQUIPMENT SERVICING IN PERTH
Don't hesitate to reach out to our friendly team with any questions.
Phone:(08) 6109 8591 or Email:Admin@ptts.com.au